CL-2160A Multi-frequency Cable Route Tracer
NEW LAUNCH!!
Multi-frequency Cable Route Tracer and Locator serves as a Pipe and Cable Tracer for underground pipelines and cables without the need for excavations. For detecting position, direction and depth of underground water pipelines, metal pipelines and cables, as well as the position and size of any damage points of the anticorrosion layer of steel pipelines, underground water pipelines, metal pipelines and cables.
- Description
- Additional information
- SPECIFICATIONS
- CATALOGUE
- Reviews (0)
Description
NEW LAUNCH!!
The Metravi CL-2160A Multi-frequency Cable Route Tracer and Locator serves as a Pipe and Cable Tracer for underground pipelines and cables without the need for excavations. It assists with:
- Accurate positioning and buried depth measurements
- Accurate search results for underground pipes outside the coating damage point
- Search for buried cable fault point location
- Metal pipeline, inspection line detection
- Pipeline management and maintenance
- Planning and construction by local municipality
- Inspections for power supply and other departments for pipeline inspections
Applications:
Detecting the position, direction and depth of underground water pipelines, metal pipelines and cables, as well as the position and size of any damage points of the anticorrosion layer of steel pipelines, underground water pipelines, metal pipelines and cables.
Underground pipelines are an important part of urban infrastructure. Urban underground pipelines, including water supply, drainage, gas, heat, telecommunications, electricity, industrial pipelines and other broad categories are very important for city or town functions.
At the same time, in the process of urban planning, design, construction and management, if there is no complete and accurate underground pipeline data or mapping, the city designers and operators become “blind”, and the same can even cause significant losses.
In recent years, with the accelerated urbanisation process and the rapid development of urban construction has increased manifold and Cable Route Locator serves an an important tool in the hands of the cities.
Additional information
Brand | |
---|---|
Model | |
Warranty | |
Display | |
GPS | GPS positioning function |
Receiver Working Mode | Broad Peak Method, Peak Arrow Method, Peak Method, Valley Method |
Receiver Depth Accuracy | ±5% |
Receiver Operating Frequency | Radio 50Hz, 100Hz, 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz |
Receiver Working Temperature | -20°C to 50°C |
Transmitter Output Power | 10W |
Depth Measurement Range | <6m |
Receiving Mode | A frame, Built-in coil, Built-in magnetic field sensor, Flexible clamp sensor |
Pipe Detection Mode | Frequency spectrum, History curve, Narrow peak method, Valley method, Wide peak method |
Cable Identification Mode | Flexible Clamp (optional) Intelligent Identification, Sensor (optional) Identification |
Receiver Power Supply | 2 X 18650 Li-on batteries, standard 7.4V, >3AH |
Receiver Charger | AC 100~240V, 50/60Hz |
Transmitter Output | Clamp Coupling Output (optional), Direct Connection Output, Fault Location Booster (optional), Radiation Output |
Over Current Protection | Auto |
Over Voltage Protection | Auto |
Transmitter Power Supply | 4 X built-in 18650 Li-on batteries, standard 7.4V, >6AH |
Transmitter Charger | DC8.4V, 2A |
Transmitter Working Mode | Clamp connection, Direct connection, Inductive connection |
Transmitter Frequency | 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz, As per the target pipeline characteristics (material, structure, depth, length, etc.), the appropriate operating frequency can be selected. |
Data Analysis Software | Optional data analysis software with automatic detection report |
Underground Detection | Detects insulation damages of underground pipelines and cables, Locates breakdown points, Measures current of the pipeline and cable applied by transmitter |
Multimeter Function | Can measure output voltage, Can test cable continuity and insulation quality before and after cable fault finding, Impedance and Power, Line current, Line voltage |
Colour |
- Transmitter has three connection modes: inductive connection, direct connection and clamp connection; hence, suitable for different applications.
- The receiver detects the position, path, depth and tube current of underground pipes and cables.
- Left and right arrows indicate the target pipeline position fast and accurately; front and rear arrows and dB value indicate the point and size of the coating damage.
- Backlit display, suitable for urgent use in the nighttime and in dark environments.
- Optional GPS geolocation with automatic mapping of the pipelines.
- Optional professional data analysis software with automatic detection report.
- Locates breakdown points (pipeline breakdowns refer to the coating damaged points while electric cable breakdowns refer to the outer layer damages.); detects the insulation damages of underground pipelines and cables.
- Measures the current of the pipeline and cable applied by the transmitter.
- Has Multimeter functions: can measure the output voltage, line voltage, line current, impedance and power; can test the cable continuity and insulation quality before and after cable fault finding.
- Comes with external induction clamp: suitable for testing cables when they cannot be directly applied to the signal of the place.
Transmitter
|
Receiver
|
|||
Output
|
Direct Connection Output, Clamp Coupling Output (optional), Radiation Output, Fault Location Booster (optional)
|
Receiving mode
|
Built-in coil, Built-in magnetic field sensor,
Flexible clamp, Sensor, A frame |
|
Output Frequency
|
128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz
|
Receiving frequency
|
Active frequency: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz. Power frequency: 50Hz/60Hz,4-24kHz Radiation frequency
|
|
Output power
|
15W max, 10 levers adjustable
|
Pipe detection mode
|
wide peak method, narrow peak method, valley method, history curve, frequency
spectrum |
|
Over voltage ,over current protection
|
auto
|
Cable identification mode
|
Flexible Clamp (optional) intelligent identification and sensor (optional) identification
|
|
HMI
|
320×240 Black and white LCD
|
HMI
|
320X240 LCD colour LCD, clear under
sunshine |
|
Power supply
|
4 X built-in 18650 Li-on batteries, standard 7.4V, >6AH
|
Built-in battery
|
2 X 18650 Li-on batteries, standard 7.4V, >3AH
|
|
Volume
|
280x220x90 mm
|
Volume
|
680x120x277 mm
|
|
Weight
|
2.3 kgs
|
Weight
|
2.0 kgs
|
|
Charger
|
DC8.4V,2A
|
Charger
|
AC 100~240V,50/60Hz
|
|
Temperature
|
-10-40℃ ; Humidity 5-90%; Elevation <4500m
|