1811 ELCB Tester
₹17,415.00 including GST @18%
Digital ELCB Tester with Current rating up to 500mA featuring Auto Ramp,Phase Switch, Reads Disconnection Time. Battery-powered.
- Description
- Video
- Additional information
- Specifications
- Catalogue
- Reviews (4)
Description
Digital ELCB RCCD Tester with Current rating up to 500mA, Auto Ramp,Phase Switch, Reads Disconnection Time, Battery-Powered
Additional information
Model | |
---|---|
Brand | |
Warranty | |
Colour | |
Display | |
Phase Angle | The RCD test can be selected to start from a positive (0°) or a negative (180°) half cycle |
Data Hold | |
Alarm | Alarm is issued when contact voltage is larger than selected limit value during RCD test |
Over Range Indication | |
Ramp Test Mode | Auto RAMP test |
Auto Power Off | |
Power Source | Battery Operated |
Battery Size | AA |
Battery Type | Alkaline |
No of Batteries | 6 |
Earthing Systems | L-N voltage measurement, L-P-E voltage measurement |
Operating Voltage | 230V/50Hz |
Frequency Range | |
Resolution | |
Accuracy | ±3% |
Certifications | CAT-III 600V, IEC-61010-1, IEC-61010-2-31, IEC-61557-1,6, Pollution Degree 2 |
Trip Current | 10/20/30/100/300/500mA |
Trip Time | 2000mS/1000mS/300mS/40mS |
Voltage Measurement Function | 30V to 600V |
- Suitable for Use on 230V/50Hz single-phase line (operating voltage: 195~253V);
- Adopts Micro-Processor Chip to maintain high accuracy, reliability and stability;
- Wiring Check: three –LED indication When P-E and P-N green LED are on and red LED is off, the wiring is correct; otherwise it indicates wrong wiring(reverse P and N or bad grounding);
- Phase Angle Selection: The tests can be performed at positive 0 or negative 180 phase angle.
- Over-Load Indication: “OL mS” shows when trip time exceeds Max. test time
- Auto Data Hold: The test results will be maintained for a while after the tests finishes.
- Auto Ramp Test: Test trip current and trip time simultaneously
- Power-Off Warning Indication: The buzzer alarms after operating for 3minutes;
- Battery Powered
- Fused Protection
- Double or Reinforced Insulation for safe design.
- Trip Current Setting: 10 / 20 / 30 / 100 / 300 / 500mA
- Confirms to IEC 61010-1 CAT III 300V, IEC 61557-1,5 and IEC 61010-2-31
View Catalogue: Metravi 1811 ELCB Tester Catalogue
kishore60kumar –
Checking an RCCB in service/post installation using 1811:
Youtube link: https://youtu.be/w3E8WeLcfHU
Kishore Kumar –
RCCB Ramp testing using Metravi 1811 RCD tester: https://youtu.be/VyQeQckVLR8
Kishore Kumar –
Metravi 1811 Ramp Test demo link:
https://youtu.be/VyQeQckVLR8
Kishore Kumar –
Sturdy, portable and accurate.