307 Digital Clamp On Power Meter

19,585.00 including GST @18%

6000 Counts, Backlit LCD, Single Phase and Three Phase, Non Contact Voltage Detector, Data Hold, Peak Hold, Relative, Max/Min Reocrd, Single Phase KW, KVA, KVAr, PF, KWh and KW & PF for Three Phase. Clamp Jaw Size 56mm. AC Current up to1500A AC.

Compare

Description

6000 Counts, Backlit LCD, Single Phase and Three Phase, Non Contact Voltage Detector, Data Hold, Peak Hold, Relative, Max/Min Reocrd, Single Phase KW, KVA, KVAr, PF, KWh and KW & PF for Three Phase. Clamp Jaw Size 56mm. AC Current up to1500A AC.

Additional information

Model

Brand

Warranty

Colour

Display

Auto Power Off

Data Hold

Relative Measurement

Relative Measurement

T-RMS

Max/Min/Avg/Dif

Low Battery Indication

Power Source

Battery Operated

Battery Type

Alkaline

Battery Size

AAA

No of Batteries

3

Jaw Dia

AC Voltage Range

AC Current Range

Frequency Range

Active Power

10W to 600kW

Apparent Power

10VA to 600kVA

Reactive Power

10VAr to 600kVAr

Power Factor

0.3 to 1

Horse Power

0.01HP to 600HP

Electrical Energy

0.01kWh to 9999

Harmonic Distortion

0.00 to 0.99

AC Voltage Accuracy

±1.2%

AC Current Accuracy

±2.5%

Frequency Accuracy

±1.0%

AC Voltage Resolution

10mV to 100mV

AC Current Resolution

0.1A to 1A

Input Impedance

1MΩ

Certifications

,

Frequency Resolution

0.1Hz to 1Hz

  • T-RMS AC Clamp On Power Clamp
  • Auto Power Off
  • Live Wire Detection
  • Min / Max and Average Recording Facility
  • Phase Sequence Indication
  • Data Hold, Peak Hold & Relative Measuring Facility
  • Electronic Overload Protection
  • Measures KW, KVA, KVAr, PF, Energy for Single Phase Loads
  • Measures Active Power and Power Factor for Three Phase Loads
  • Clamp Jaw Size : 56mm
  • Display : 6000 Counts Backlit LCD
  • AC Voltage : 0 – 60/600V. T-RMS
  • Accuracy : ±1.0%
  • AC Current : 0 – 600/1500A. T-RMS
  • Accuracy : ±2.5%
  • Frequency : 0 – 200 / 2kHz
  • Accuracy : ±1%
  • Active Power : 10W ~ 600kW
  • Accuracy : ±2.5%
  • Horse Power : 0.01HP ~ 600HP
  • Accuracy : ±2.5%
  • Apparent Power : 10VA ~ 600kVA
  • Accuracy : ±2.5%
  • Reactive Power : 10VAr ~ 600kVAr
  • Accuracy : ±2.5%
  • Electrical Energy : 0.01 ~ 9999kWh
  • Accuracy : ±2.5%
  • Power Factor : 0.3 ~ 1.00
  • Accuracy : ±2.5%
  • Total Harmonic Distortion: 0.00 ~ 0.99
  • Accuracy : ±2.5%
  • Complies with EN 61010-I (2000 Version), CAT III 600V

Reviews

There are no reviews yet.


Be the first to review “307 Digital Clamp On Power Meter”