M-01S mV Thermocouple and RTD Source Calibrator
₹39,150.00 including GST @18%
NEW LAUNCH!!
5 Digits LCD Display, 0.05% accuracy, provides output only for DC Voltage, Resistance, Thermocouples – R, S, K, E, J, T, N, B, A, C, D and Thermal Resistance RTD – PT-100, PT-200, PT-500, PT-1000, Cu-50.
The output temperature value and the corresponding temperature signal are displayed on the same screen. With Auto power-off, backlight, flashlight.
- Description
- Additional information
- Specifications
- Catalogue
- Reviews (0)
Description
NEW LAUNCH!!
The Metravi M-01S mV Thermocouple & RTD Source Calibrator features a basic accuracy of 0.05% and a 5 digits display for nmeasured value. With a resolution of 0.1°C and the output unit can be converted between °C and °F.
It features 8 types of analogue output (R/S/K/E/J/T/B/N) for thermocouple. DCV output provides extra range for temperature output. The phase compensation of output make it possible for instrument to drive a load with capacitance up to 2000μf, matching for applications with the filter of large capacitance at the input terminal.
It also features 7 types of thermistor outputs (Cu50, PT100, PT200, PT500, PT1000). Resistor output provides extra range of
temperature output. The response time of current input is less than 5ms. It can be used as the signal source of instruments with pulse input (such as DCS, PLC temperature detector) and secondary instruments.
Temperature compensation with high accuracy at the cold terminal is designed for the thermocouple output. Also comes with
adjustable output gain, is easy in operation, has built-in self-tests with closed-case calibration (no internal calibration adjustment).
Features:
• Analogue output.
• Output for DC Voltage DCV, Resistance OHM, Thermocouple TC, Thermal Resistance RTD Source.
• Output temperature value and the corresponding temperature signal are displayed simultaneously.
• Built-in high-precision temperature sensor for high-precision cold-end compensation.
• Thermocouple cold-end compensation can be set, including manual compensation, automatic compensation, compensation access disconnection, etc.
• Auto power-off.
• The segment code is displayed on the LCD with a white backlight.
• LED flashlight.
• Powered by 3 AA battery cells. The battery compartment door is convenient for battery replacement. Low-battery indication.
• Compact, firm, reliable, suitable for field use.
Additional information
| Brand | |
|---|---|
| Model | |
| Colour | |
| Warranty | |
| Operating temperature and humidity | 0 to 50ºC; ≤80%RH without condensation, 40 to 50ºC ≤70%RH |
| Storage temperature and humidity | -25 to 60ºC, ≤90%RH without condensation |
| Electrical safety | CE, EN61010-1:2001 |
| Withstand Voltage | AC3540V (50/60Hz) / 5 seconds between terminal and housing |
| Electromagnetic Compatibility | EN61326-1:2006 |
| Protection Level | 1m drop-tested, IP40 |
| Vibration and fall | IEC 60068-2-32:2008, IEC 60068-2-64:2008 |
| Quality standard | developed, designed and manufactured in accordance with TUV ISO-9001 |
| Preheating time | Startup preheating time is more than 30 minutes |
| LCD Display | 5 digits, segment code LCD with white backlight |
| Power Supply | 3 x AA alkaline batteries |
| Accessories | 1 pair Industrial test leads, 3 units AA alkaline battery, Thermocouple Adapter |
| Dimensions | 9.84 x 3.94 x 7.87 inches |
| Weight | 600gms approx |
| DC Voltage Output | 10mV to 1.1V |
| Resistance Output: | 0.1Ω to 4kΩ |
| PT-100 Output | -200.0°C to 800.0°C |
| K-Type Thermocouple O/P | -200.0°C to 1372.0°C |
| J-Type Thermocouple O/P | -200.0°C to 1372.0°C |
| R-Type Thermocouple O/P | 0.0°C to 1767.0°C |
| E-Type Thermocouple O/P | -200.0°C to 1000.0°C |
| N-Type Thermocouple O/P | -200.0°C to 1300.0°C |
- DC Voltage: -10.000mV~110.00mV-0.1000V~1.1000V
- Accuracy: 0.05%+0.03mV / 0.05%+0.3mV
- Resolution: 0.01mV / 0.0001V
- Resistance: 0~400.0Ω / 0~4.000KΩ
- Accuracy: 0.05%+0.2Ω / 0.05%+2Ω
- Resolution: 0.1Ω / 1Ω
- R-type Thermocouple Range: 0°C~1767°C
- S-type Thermocouple Range: 0°C~1767°C
- K-type Thermocouple Range: -200.0°C~1372.0°C
- E-type Thermocouple Range: -200.0°C~1000.0°C
- J-type Thermocouple Range: -200.0°C~1200.0°C
- T-type Thermocouple Range: -250.0°C~400.0°C
- N-type Thermocouple Range: -200.0°C~1300.0°C
- B-type Thermocouple Range: 600°C~1820°C
- A-type Thermocouple Range: 0°C~2500°C
- C-type Thermocouple Range: 0°C~2310°C
- D-type Thermocouple Range: 0°C~2310°C
- Thermal Resistance PT100: -200.0°C~800.0°C
- Thermal Resistance PT200: -200.0°C~630.0°C
- Thermal Resistance PT500: -200.0°C~630.0°C
- Thermal Resistance PT1000: -200.0°C~630.0°C
- Thermal Resistance Cu50: -50.0°C~150.0°C
- Electrical safety : EN61010-1:2001, CE, TUV ISO-9001 Electromagnetic compatibility (EMC) : EN61326-1:2006
- Protection : IP40, 1m drop-tested
- Vibration and fall : IEC 60068-2-64:2008, IEC 60068-2-32:2008
- Display : 5 digits, segment code LCD with white backlight
- Power Supply : 3 x AA alkaline batteries
- Accessories : 1 pair Industrial test leads, User Manual, 3 units AA alkaline Battery, Thermocouple Adapter
View Catalogue: Metravi M-01S mV Thermocouple & RTD Source Calibrator Catalogue
Be the first to review “M-01S mV Thermocouple and RTD Source Calibrator”
You must be logged in to post a review.













Reviews
There are no reviews yet.